Cleaning machine Vials Ampulle

Machine type FAW 1005

The cleaning machines of the FAW series are designed for wet cleaning of vials, ampoules and similar types of container, including non-stable containers, to pharmaceutical industry standards. The containers are conveyed through the work area very gently in an intermittent flow. By using the pressure-controlled rinsing and spraying system and various cleaning media, optimal pharma-compliant cleaning of all containers is assured. The various cleaning media can be used in any chosen order, and the line system is configured in such a way that media do not mix.

HIGHLIGHTS

  • Effective and thorough cleaning
  • Pharmaceutical design
  • Cleaning schematic is freely selectable
  • Cleaning media cannot mix
  • FAW 1005
  • FAW 1005
Type of machineOutputProcessing range
FAW1005
  • up to 6,000 items/h
  • Container diameter: 7.5 - 52 mm
  • Container height: 22 - 140 mm
Technical data depend on machine equipment and packaging.
Easy and centralized operation
Short set-up time
Gentle container transport
Pre-cleaning in an ultrasonic bath
  • Water recycling station for the recirculation, regeneration and multiple use of a cleaning medium
  • ECOwash – container-optimized cleaning needles
  • Other container exterior cleaning stations
  • Additional container exterior blow-cleaning stations
  • Purging of the water lines
  • Fine and HEPA filters
  • Differential pressure monitoring system for filters
  • Software upgrades
  • Qualification (IQ/OQ)



The ECOwash system by Bausch + Ströbel ensures optimal cleaning of all containers while significantly reducing the consumption of cleaning media. This is achieved by using a combination of special cleaning needles which are developed and/or adapted in comprehensive trials to meet your specific requirements. The ECOwash (Efficient Customized Operation) technology has the following advantages:
  • Optimized cleaning in hard-to-reach areas
  • Reduction in water consumption: up to 40%
  • Reduction in residual moisture content: up to 70%
  • Reduction in air consumption: up to 20%
  • Reduction in noise when blow-drying containers: up to 50%
  • High energy efficiency
This technology meets the applicable GMP requirements and the FDA guideline on electronic data records (21 CFR Part 11). This technology can be retrofitted to existing rinsing machines.

Downstream processing stages

Machine type DHT 2431

DHT

Sterilizing tunnel

Container typesAmpulleVials